Lung Volume (hypoinflation / hyperdistention), Fractures, Bone and Catheters / Tubes / Implanted Devices
What does this chest radiograph show?
This chest radiograph is indexed in the Indiana University Chest X-ray Collection under “Fractures, Bone, Lung Volume (hypoinflation / hyperdistention) and Catheters / Tubes / Implanted Devices”. The principal recorded finding is “Lung Volume (hypoinflation / hyperdistention)”, and the case status is documented as “Active or unspecified chronicity”. Recorded descriptors for this case include severity Hypoinflation and Mild. The structured record behind this page carries 3 indexed terms; in the source report text, a findings section and an impression are present, with no comparison study recorded. The study comprises 2 views.
This summary is composed from the collection's structured annotation fields, and is not a description of the image.
- Severity and descriptors: Hypoinflation and Mild
- Diagnostic category: Lung Volume (hypoinflation / hyperdistention), Fractures, Bone and Catheters / Tubes / Implanted Devices
- Imaging coverage: 2 views, native resolution 512x512 pixels
- Related keywords: Fractures, Bone, Lung Volume (hypoinflation / hyperdistention), Catheters / Tubes / Implanted Devices, Lung, Surgical Instruments and Sternum
Radiologist's Diagnostic Impression (analytical summary)
Recorded findings: Lung Volume (hypoinflation / hyperdistention), Fractures, Bone, Catheters / Tubes / Implanted Devices, Fractures, Bone (Sternum) and Lung (Hypoinflation, Mild). Categories: “Fractures, Bone, Lung Volume (hypoinflation / hyperdistention) and Catheters / Tubes / Implanted Devices”. Status: “Active or unspecified chronicity”.
Case Radiographs (2 Views)
Radiographic Study Specifications
- Case Number
- CXR 1619
- Modality
- Chest Radiography (X-Ray)
- Views
- 2 images
- Clinical Status
- Active or unspecified chronicity
Primary Clinical Report (verbatim source text - NoDerivatives)
- Indication
- Chest pain.
- Findings
- The cardiomediastinal silhouette and pulmonary vasculature are within normal limits in size. The lungs are mildly hypoinflated but clear of focal airspace disease, pneumothorax, or pleural effusion. There are multiple median sternotomy wires and surgical clips compatible with prior CABG. The most caudal median sternotomy wires is fractured. There are no acute bony findings.
- Impression
- 1. Low lung volumes. No acute pulmonary findings. 2. Fractured median sternotomy wires, without evidence of complication.
Related Radiology Cases
Source, Scientific Provenance and Licence
Indiana University Chest X-ray Collection · Open-i / U.S. National Library of Medicine · CC BY-NC-ND 4.0
Licence: CC BY-NC-ND 4.0
Primary Data Source: https://openi.nlm.nih.gov/