ECG #1590 — Non-specific st changes

PTB-XL Record #01590 · 12-Lead Diagnostic Electrocardiogram · 500 Hz High-Resolution

12-Lead Electrocardiogram Preview #1590
Target Territory: Full 12-Lead Baseline
I II III aVR aVL aVF V1 V2 V3 V4 V5 V6
Heart Rate
54.3 bpm
PR Interval
150 ms
QRS Duration
100 ms
QTc (Bazett)
390.0 ms
Frontal QRS Axis
+22.1° (Normal)
Demographics
87 yrs · Male

Clinical Direct Answer

The primary diagnostic finding on this 12-lead electrocardiogram is non-specific ST changes, recorded with an underlying rhythm of sinus rhythm at a rate of 54.3 beats per minute (bradycardia). Pathological waveform alterations are predominantly localized to target territory leads, requiring prompt clinical correlation, serial biomarkers, and targeted electrophysiological evaluation.

Comprehensive 7-Step Electrophysiological Interpretation

1

Rhythm & Pacemaker Origin

The baseline rhythm is Sinus Bradycardia with intact 1:1 atrioventricular conduction. Electrical depolarization originates physiologically from pacemaker cells in the sinoatrial (SA) node in the superior right atrium, firing at a depressed intrinsic rate modulated by parasympathetic tone. P-wave morphology is uniform and upright in leads II, III, and aVF.

2

Ventricular Rate & Regularity

The resting ventricular heart rate is quantified at 54.3 beats per minute (bpm) with a median R-R interval of 1105 ms. This rate is under 60 bpm, categorizing this record as sinus bradycardia, providing prolonged diastolic ventricular filling time.

3

Frontal Plane QRS Axis & Vector Analysis

The mean frontal plane QRS electrical axis is calculated at 22.1° (Normal Axis). The axis falls within the physiologic normal range (-30° to +90°). The mean depolarization vector propagates inferiorly and leftward, reflecting normal left ventricular dominance.

4

Conduction Intervals & Chamber Timing (PR, QRS, QT/QTc)

Electrophysiologic interval analysis: PR interval is normal at 150 ms (normal range 120-200 ms), confirming physiological transmission velocity across the atrioventricular node. QRS complex is narrow at 100 ms (<100 ms), validating rapid, synchronized biventricular activation via the specialized His-Purkinje network. Bazett-corrected QTc (QTc = QT / √RR) is measured at 390.0 ms (raw QT: 410 ms), resting comfortably within safe gender-specific limits for males and confirming stable ventricular repolarization.

5

Waveform Morphology & ST-T Segment Dynamics

ST-segment and T-wave morphology indicates repolarization abnormalities secondary to ischemia (non-specific ST changes). Subendocardial ischemia manifests through horizontal or downsloping ST depressions and symmetric T-wave inversions in corresponding territory leads.

6

Clinical Correlation & Pathophysiological Significance

Biophysical clinical correlation: Considering this patient's age of 87 years (male), age-associated degenerative fibrosis of the cardiac skeleton and conduction tissue is common; preserved conduction intervals and absence of advanced AV blocks confirm satisfactory resting conduction system integrity. Furthermore, calculated QTc intervals and resting heart rate closely align with metabolic perfusion demands for this demographic group.

7

Differential Diagnosis & Recommended Diagnostic Workup

Key differential diagnoses include: 1. Left ventricular strain pattern 2. Digitalis effect (scooped ST depression) 3. Electrolyte derangements such as hypokalemia 4. Acute pulmonary embolism (right ventricular strain) 5. Coronary vasospasm (Prinzmetal angina).

Interactive 12-Lead Signal & Digital Caliper

Select individual leads to examine high-resolution waveforms and measure precise intervals in milliseconds.

Click two points on the tracing to measure interval
Clinical & Educational Notice: This electrocardiogram analysis is generated from the PTB-XL open clinical cohort for educational, reference, and computational research purposes. It does not replace individualized bedside clinical evaluation, emergency triage, or formal cardiologist consultation.