ECG #102 — First degree av block

PTB-XL Record #00102 · 12-Lead Diagnostic Electrocardiogram · 500 Hz High-Resolution

12-Lead Electrocardiogram Preview #102
Target Territory: First-Degree AV Block Tracing
I II III aVR aVL aVF V1 V2 V3 V4 V5 V6
Heart Rate
83.3 bpm
PR Interval
260 ms
QRS Duration
100 ms
QTc (Bazett)
447.8 ms
Frontal QRS Axis
+8.4° (Normal)
Demographics
64 yrs · Male

Clinical Direct Answer

The primary diagnostic finding on this 12-lead electrocardiogram is first degree AV block, recorded with an underlying rhythm of sinus rhythm at a rate of 83.3 beats per minute (normal rate). Pathological waveform alterations are predominantly localized to target territory leads, requiring prompt clinical correlation, serial biomarkers, and targeted electrophysiological evaluation.

Comprehensive 7-Step Electrophysiological Interpretation

1

Rhythm & Pacemaker Origin

The electrocardiogram displays Normal Sinus Rhythm (NSR) with steady regular sequence and intact 1:1 atrioventricular relationship. Cardiac activation initiates normally within the sinoatrial (SA) node in the high posterior right atrium, spreading through the internodal pathways to the AV node. P waves are distinct, uniform, and upright in inferior leads.

2

Ventricular Rate & Regularity

The resting ventricular heart rate is quantified at 83.3 beats per minute (bpm) with a median R-R interval of 720 ms. This rate is within the physiologic normocardia range (60 to 100 bpm), reflecting balanced resting sympathovagal tone and stable cardiac output.

3

Frontal Plane QRS Axis & Vector Analysis

The mean frontal plane QRS electrical axis is calculated at 8.4° (Normal Axis). The axis falls within the physiologic normal range (-30° to +90°). The mean depolarization vector propagates inferiorly and leftward, reflecting normal left ventricular dominance.

4

Conduction Intervals & Chamber Timing (PR, QRS, QT/QTc)

Electrophysiologic interval analysis: PR interval is prolonged at 260 ms (>200 ms), diagnostic of First-Degree Atrioventricular Block with decremental AV nodal conduction delay. QRS complex is narrow at 100 ms (<100 ms), validating rapid, synchronized biventricular activation via the specialized His-Purkinje network. Bazett-corrected QTc (QTc = QT / √RR) is measured at 447.8 ms (raw QT: 380 ms), resting comfortably within safe gender-specific limits for males and confirming stable ventricular repolarization.

5

Waveform Morphology & ST-T Segment Dynamics

Precordial and frontal QRS morphology reveals diagnostic bundle branch delay (first degree AV block). Notched wide QRS deflections coupled with secondary ST-segment and T-wave repolarization discordance reflect sequential rather than simultaneous biventricular depolarization.

6

Clinical Correlation & Pathophysiological Significance

Biophysical clinical correlation: In this 64-year-old male patient, electrocardiographic parameters must be framed within adult cardiovascular risk profiles (hypertension, metabolic profile, and lifestyle); intact intervals and isoelectric baselines reflect resting myocardial stability. Furthermore, calculated QTc intervals and resting heart rate closely align with metabolic perfusion demands for this demographic group.

7

Differential Diagnosis & Recommended Diagnostic Workup

Key differential diagnoses include: 1. Ventricular Paced Rhythm 2. Wolff-Parkinson-White pre-excitation syndrome (short PR with delta wave) 3. Ventricular Tachycardia 4. Non-specific intraventricular conduction delay (IVCD) 5. Sodium-channel blocker toxicity.

Interactive 12-Lead Signal & Digital Caliper

Select individual leads to examine high-resolution waveforms and measure precise intervals in milliseconds.

Click two points on the tracing to measure interval
Clinical & Educational Notice: This electrocardiogram analysis is generated from the PTB-XL open clinical cohort for educational, reference, and computational research purposes. It does not replace individualized bedside clinical evaluation, emergency triage, or formal cardiologist consultation.