ECG #1508 — Left ventricular hypertrophy

PTB-XL Record #01508 · 12-Lead Diagnostic Electrocardiogram · 500 Hz High-Resolution

12-Lead Electrocardiogram Preview #1508
Target Territory: Left Ventricular Precordial Voltage
I II III aVR aVL aVF V1 V2 V3 V4 V5 V6
Heart Rate
120.0 bpm
PR Interval
—
QRS Duration
90 ms
QTc (Bazett)
396.0 ms
Frontal QRS Axis
-32.6° (Left Axis Deviation)
Demographics
81 yrs · Male

Clinical Direct Answer

The primary diagnostic finding on this 12-lead electrocardiogram is atrial fibrillation, recorded with an underlying rhythm of atrial fibrillation at a rate of 120.0 beats per minute (tachycardia). Pathological waveform alterations are predominantly localized to target territory leads, requiring prompt clinical correlation, serial biomarkers, and targeted electrophysiological evaluation.

Comprehensive 7-Step Electrophysiological Interpretation

1

Rhythm & Pacemaker Origin

The underlying rhythm is Atrial Fibrillation (AFib) with variable atrioventricular conduction. Electrophysiological impulse generation stems from disorganized, high-frequency ectopic micro-reentry circuits within the atrial myocardium, predominantly localized near the pulmonary vein ostia. The tracing features complete absence of discrete P waves, continuous baseline fibrillatory f-waves, and an irregularly irregular ventricular response.

2

Ventricular Rate & Regularity

The resting ventricular heart rate is quantified at 120.0 beats per minute (bpm) with a median R-R interval of 500 ms. This rate is exceeding 100 bpm, categorizing this record as sinus tachycardia, which attenuates coronary perfusion time during shortened diastole.

3

Frontal Plane QRS Axis & Vector Analysis

The mean frontal plane QRS electrical axis is calculated at -32.6° (Left Axis Deviation (LAD)). Displays Left Axis Deviation (-30° to -90°). Depolarization is directed superiorly and leftward, consistent with left anterior fascicular block (LAFB), left ventricular hypertrophy, or inferior wall scar.

4

Conduction Intervals & Chamber Timing (PR, QRS, QT/QTc)

Electrophysiologic interval analysis: PR interval is non-measurable due to fibrillatory baseline activity or absence of discrete P waves. QRS complex is narrow at 90 ms (<100 ms), validating rapid, synchronized biventricular activation via the specialized His-Purkinje network. Bazett-corrected QTc (QTc = QT / √RR) is measured at 396.0 ms (raw QT: 280 ms), resting comfortably within safe gender-specific limits for males and confirming stable ventricular repolarization.

5

Waveform Morphology & ST-T Segment Dynamics

P-wave morphology across all 12 leads is unremarkable, without evidence of right or left atrial enlargement. Precordial R-wave progression from lead V1 to V6 is physiological with a normal transition zone at V3-V4. ST segments remain strictly isoelectric throughout, devoid of pathologic elevations or depressions, and T waves exhibit normal upright symmetry concordant with QRS vectors.

6

Clinical Correlation & Pathophysiological Significance

Biophysical clinical correlation: Considering this patient's age of 81 years (male), age-associated degenerative fibrosis of the cardiac skeleton and conduction tissue is common; preserved conduction intervals and absence of advanced AV blocks confirm satisfactory resting conduction system integrity. Furthermore, calculated QTc intervals and resting heart rate closely align with metabolic perfusion demands for this demographic group.

7

Differential Diagnosis & Recommended Diagnostic Workup

Key differential diagnoses for this normal tracing include: 1. Normal physiologic variant 2. Benign early repolarization variant 3. Transient autonomic fluctuations secondary to anxiety or hyperventilation 4. Subclinical coronary artery disease (normal at rest, requiring stress testing if symptomatic) 5. Minor electrode positioning artifact.

Interactive 12-Lead Signal & Digital Caliper

Select individual leads to examine high-resolution waveforms and measure precise intervals in milliseconds.

Click two points on the tracing to measure interval
Clinical & Educational Notice: This electrocardiogram analysis is generated from the PTB-XL open clinical cohort for educational, reference, and computational research purposes. It does not replace individualized bedside clinical evaluation, emergency triage, or formal cardiologist consultation.