Rhythm & Pacemaker Origin
The dominant rhythm is Atrial Flutter. Impulse propagation is driven by an organized right atrial macro-reentrant circuit incorporating the cavotricuspid isthmus (CTI). Characteristic regular sawtooth flutter waves (F waves) are evident, conducted to the ventricles across the AV node in a fixed or variable ratio.