Back to Hematology
Hematologyv2021Evidence-Based

Corrected Count Increment (CCI) for Platelet Transfusion

Assesses adequacy of response to platelet transfusion by measuring the expected increase in platelets adjusted for patient size and platelet dose

Clinical Input Parameters

platelets/μL
Range: 0 — 500000 platelets/μL
platelets/μL
Range: 0 — 500000 platelets/μL
inches
Range: 48 — 90 inches
lbs
Range: 0.5 — 620 lbs
×10¹¹ platelets
Range: 0.5 — 500 ×10¹¹ platelets
Clinical Assessment
Awaiting Parameters
cci value
—platelets/μL/m²/(×10¹¹ platelets)
Ready to Calculate

Awaiting Clinical Input

Enter the clinical input parameters on the left and click Run Clinical Assessment to evaluate this medical calculator with deterministic clinical scoring.

Open in Web App
Clinical decision support tool for licensed medical practitioners. Confirm independently before prescribing or clinical action.

When & Why to Use

The Corrected Count Increment (CCI) for Platelet Transfusion is utilized in clinical practice for risk stratification, diagnostic probability estimation, and treatment decision-making within hematology.

Use this tool during initial patient intake, emergency department workup, or bedside assessment when objective clinical scoring is required to guide management or admission decisions.

Clinical Formula & Scoring Logic

CCI = (Post-transfusion count - Pre-transfusion count) × BSA / Platelet dose, where BSA = sqrt((height_cm × weight_kg) / 3600)

Clinical Pearls & Practice Notes

  • CCI >7,500 at 1 hour indicates successful transfusion
  • CCI >4,800 at 20 hours indicates successful transfusion
  • Lower CCI values may indicate platelet refractoriness
  • Platelet refractoriness defined as failure to achieve acceptable platelet increment on ≥2 occasions
  • Alternative causes of poor response: fever, sepsis, DIC, bleeding, splenomegaly, drug interactions

Evidence & Literature Citations

  1. Davis KB, Slichter SJ, Corash L. Corrected count increment and percent platelet recovery as measures of posttransfusion platelet response: problems and a solution. Transfusion. 1999;39(6):586-92.
  2. Bishop JF, Matthews JP, McGrath K, Yuen K, Wolf MM, Szer J. Factors influencing 20-hour increments after platelet transfusion. Transfusion. 1991;31(5):392-6.
  3. Slichter SJ, Davis K, Enright H, et al. Factors affecting posttransfusion platelet increments, platelet refractoriness, and platelet transfusion intervals in thrombocytopenic patients. Blood. 2005;105(10):4106-14.

Score Interpretation Ranges

Successful Transfusion7500 – pts

Good platelet response at 1 hour

Poor Response – 7500 pts

Inadequate platelet response at 1 hour

Successful Transfusion4800 – pts

Good platelet response at 20 hours

Poor Response – 4800 pts

Inadequate platelet response at 20 hours

Need Clinical Suite Access?

Run this calculator with patient history, laboratory integration, and drug interaction safety checks on the DexaMed clinician app.

Open in Web App

Clinical Decision Support (CDS) Notice & Legal Disclaimer

This medical calculator and its scoring interpretation are provided strictly for licensed healthcare professionals and medical trainees as an educational and clinical decision support instrument. It does not replace independent clinical judgment, comprehensive patient history, physical examination, or attending physician oversight. Not FDA-cleared as an autonomous diagnostic medical device. Read the full DexaMed Medical Disclaimer.