Back to Cardiology
Cardiologyv1986Evidence-Based

Cardiac Power Output (CPO)

Calculates cardiac power output, the rate of energy output of the heart. Integrates both pressure and flow components of cardiac work. Strong hemodynamic predictor of mortality in cardiogenic shock.

Clinical Input Parameters

mmHg
Range: 30 — 200 mmHg
L/min
Range: 1 — 15 L/min
mmHg
Range: 0 — 30 mmHg
Clinical Assessment
Awaiting Parameters
cardiac power output
—Watts
Ready to Calculate

Awaiting Clinical Input

Enter the clinical input parameters on the left and click Run Clinical Assessment to evaluate this medical calculator with deterministic clinical scoring.

Open in Web App
Clinical decision support tool for licensed medical practitioners. Confirm independently before prescribing or clinical action.

When & Why to Use

The Cardiac Power Output (CPO) is utilized in clinical practice for risk stratification, diagnostic probability estimation, and treatment decision-making within cardiology.

Use this tool during initial patient intake, emergency department workup, or bedside assessment when objective clinical scoring is required to guide management or admission decisions.

Clinical Formula & Scoring Logic

Standard CPO = (MAP × CO) / 451. Original Tan formula: CPO-RAP = [(MAP - RAP) × CO] / 451. Where MAP = mean arterial pressure (mmHg), CO = cardiac output (L/min), RAP = right atrial pressure (mmHg), 451 = conversion constant

Clinical Pearls & Practice Notes

  • CPO is the strongest hemodynamic predictor of mortality in cardiogenic shock
  • Normal resting CPO is approximately 1.0 Watt
  • CPO <0.6W indicates severe ventricular dysfunction with poor prognosis
  • Exercise can increase CPO reserve up to 6 Watts
  • Original Tan 1986 formula included right atrial pressure (RAP) component
  • Including RAP provides better prognostic performance, especially in elevated filling pressures
  • Standard formula (without RAP) may overestimate CPO in cardiogenic shock
  • Used for initial risk stratification and tracking response to therapy
  • Not validated for noncardiogenic or pure distributive shock
  • Constant 451 converts pressure-flow product to normal resting CPO of 1.0W
  • Can guide inotrope titration to achieve target CPO >0.6W

Evidence & Literature Citations

  1. Tan LB. Cardiac pumping capability and prognosis in heart failure. Lancet. 1986 Dec 13;2(8520):1360-3. doi: 10.1016/s0140-6736(86)92002-6.
  2. Fincke R, Hochman JS, Lowe AM, et al. Cardiac power is the strongest hemodynamic correlate of mortality in cardiogenic shock: a report from the SHOCK trial registry. J Am Coll Cardiol. 2004 Jul 21;44(2):340-8. doi: 10.1016/j.jacc.2004.03.060.
  3. Mendoza DD, Cooper HA, Panza JA. Cardiac power output predicts mortality across a broad spectrum of patients with acute cardiac disease. Am Heart J. 2007 Mar;153(3):366-70. doi: 10.1016/j.ahj.2006.11.014.
  4. Williams SG, Cooke GA, Wright DJ, et al. Peak exercise cardiac power output; a direct indicator of cardiac function strongly predictive of prognosis in chronic heart failure. Eur Heart J. 2001 Aug;22(16):1496-503. doi: 10.1053/euhj.2000.2547.

Score Interpretation Ranges

Severe dysfunction0 – 0.6 pts

Severe ventricular dysfunction

Moderately reduced0.6 – 1 pts

Moderately reduced cardiac power

Normal to high1 – 6 pts

Normal to high cardiac power

Need Clinical Suite Access?

Run this calculator with patient history, laboratory integration, and drug interaction safety checks on the DexaMed clinician app.

Open in Web App

Clinical Decision Support (CDS) Notice & Legal Disclaimer

This medical calculator and its scoring interpretation are provided strictly for licensed healthcare professionals and medical trainees as an educational and clinical decision support instrument. It does not replace independent clinical judgment, comprehensive patient history, physical examination, or attending physician oversight. Not FDA-cleared as an autonomous diagnostic medical device. Read the full DexaMed Medical Disclaimer.